Phone: (308) 345-3670 | Fax: (308) 345-7880

Special Handling Requirements for Water, Wastewater, & Manure Samples

Sample bottles are available from the laboratory at no charge.

Sterile bottles must be used for water analysis to obtain valid results.

Please call the laboratory to order these bottles.

 

Analyte Sample Container Size, ml Preservation Holding Time
Ammonia Plastic 100 H2SO4 to pH <2, refrigerate 28 days
Alkalinity Plastic 100 Refrigerate 14 days
BOD/c-BOD Plastic 1000 Refrigerate 48 hours
Boron Plastic 100 None 6 months
COD Plastic 1000 H2SO4 to pH <2, refrigerate 28 days
Chloride Plastic 100 None 28 days
Coliform Bacteria Plastic 100 Sterile bottle from lab 30 hours
Conductivity Plastic 100 Refrigerate 28 days
Cyanide Plastic 1000 NaOH to pH >12 14 days
Fluoride Plastic 100 None 28 days
Hardness Plastic 100 HNO3 to pH <2 6 months
Metals Plastic 100 HNO3 to pH <2 6 months
Nitrate Plastic 100 Refrigerate 48 hours
Nitrate + Nitrite Plastic 100 H2SO4 to pH <2, refrigerate 28 days
Oil and Grease Glass 1000  HCl to pH <2, refrigerate 28 days
Pesticides Glass, TFE Cap 1000 Refrigerate 7 days
pH Plastic 100 Refrigerate 48 hours
Solids (TSS, TDS) Plastic 1000 Refrigerate 7 days
Sulfate Plastic 100 Refrigerate 7 days
Total Nitrogen Plastic 1000 H2SO4 to pH <2, refrigerate 28 days